| Test report approved by ERDA |

|
| CT / PT METERING UNITS |
| ITEM |
CT/PT METERING UNITS 33 KV, 22 KV, 11 KV |
| APPLICATION |
POWER STATIONS & MAJOR POWER CONSUMERS WHO METER ENERGY CONSUMPTION MAXIMUM DEMAND ETC. |
| SPECIFICATION |
INPUT : 33 KV, 11KV, 3PH 50 HZ A.C
OUTPUT IN VOLTAGE : 110V-3 PH 40 HZ A.C
CURRENT : 5 AMP.
VA FOR VOLTAGE : PT - 100
VA FOR CURRENT : CT - 15
CLASS OF ACCURACY : 1% / 0.5% ERROR
SYSTEM VOLTAGE : 12KV (11KV), 24KV (22KV) 36KV (33KV)
INSULATION LEVEL : 28KV, 50KV, 75KV
IMPULSE VOLTAGE :
IMPULSE CURRENT :
COOLING : AN ON
|
| BENIFITS |
COMPACT DESIGN, CONFIRMING TO RELEVANT STANDARD, LONG LIFE. |
|
| Test report approved by ERDA |

|
| CT / PT METERING UNITS |
| ITEM |
CT/PT METERING UNITS 33 KV, 22 KV, 11 KV |
| APPLICATION |
POWER STATIONS & MAJOR POWER CONSUMERS WHO METER ENERGY CONSUMPTION MAXIMUM DEMAND ETC. |
| SPECIFICATION |
INPUT : 33 KV, 11KV, 3PH 50 HZ A.C
OUTPUT IN VOLTAGE : 110V-3 PH 40 HZ A.C
CURRENT : 5 AMP.
VA FOR VOLTAGE : PT - 100
VA FOR CURRENT : CT - 15
CLASS OF ACCURACY : 1% / 0.5% ERROR
SYSTEM VOLTAGE : 12KV (11KV), 24KV (22KV) 36KV (33KV)
INSULATION LEVEL : 28KV, 50KV, 75KV
IMPULSE VOLTAGE :
IMPULSE CURRENT :
COOLING : AN ON
|
| BENIFITS |
COMPACT DESIGN, CONFIRMING TO RELEVANT STANDARD, LONG LIFE. |
|

|
| IGNITION TRANSFORMER |
| ITEM |
IGNITION TRANSFORMER OF 5 KV, 7.5 KV, 10 KV, 12 KV, 14.5 KV. |
| APPLICATION |
FURNACES IN WHICH SPARK IGNITION IS USED. |
| SPECIFICATION |
INPUT : 230 V, 1 PH 50 HZ A.C
OUTPUT : 5 KV, 7.5 KV, 10 K.V, 12 K.V, 14.5 KV.
CURRENT : 20MA, 35MA
DUTY : CONTINUOUS / INTERMITTENT
TYPE : EPOXY RESIN / DAMPER MOLDED
|
| BENIFITS |
COMPACT DESIGN, MAINTENANCE FREE, LONG LIFE PANEL MOUNTABLE. |
|

|
| BATTERY CHARGER (FLOAT & BOOST) |
| ITEM |
BATTERY CHARGES OF ALL TYPES OF SECONDARY CELLS OF ALL CAPACITY. |
| APPLICATION |
BACKUP POWER SUPPLY FOR POWER STATIONS, CONTINUOUS PRODUCTION UNITS, RAILWAYS, HOSPITALS, HOTELS, COMMUNICATION SYSTEMS, COMPUTER INSTALLATIONS ETC. |
| SPECIFICATION |
INPUT : 230 / 440 V - 1PH / 3 PH, 50 HZ A.C.
OUTPUT : D.C UP TO 230 / 440 V ETC.
O/P CAPACITY : AS PER REQUIREMENT (OPTIONAL)
RECTIFICATION : DIODE / SCR, FULL WAVE / HALF WAVE CONTROLLED DIRECT.
RIPPLE / FILTERING : RIPPLE AS PER REQUIREMENT.
FILTERING ADOPTED.
EFFICIENCY : MORE THAN 80%
POWER FACTOR : 08
MODE OF OPERATION : INITIAL, BOOST, FLOAT, TRICKLE.
CONTROL : MANUAL / AUTOMATIC
DUTY : CONTINUOUS
OVERLOAD : 50 % FOR 1 HOUR
COOLING : A.N
INSTALLATION : INDOOR / OUTDOOR, FIXED / PORTABLE (OPTIONAL)
|
| BENIFITS |
SINGLE CUBICLE CONSTRUCTIONS, VOLTAGE AND CURRENT SELECTION, AUTOMATIC VOLTAGE AND CURRENT REGULATOR, DIGITAL / ANALOG METERING (OPTIONAL), OPERATION MODE FACILITY, PROTECTION FOR TRANSFORMERS & RECTIFIER UNITS, LONG LIFE & LESS MAINTENANCE, RISK FREE OPERATION
|
|

|
| INSTRUMENT TRANSFORMER |
| ITEM |
INSTRUMENT TRANSFORMER UP TO 22 KV, CURRENT TRANSFORMERS AND POTENTIAL TRANSFORMERS. |
| APPLICATION |
FOR METERING OF HIGH VOLTAGE & CURRENT OF DIFFERENT POWER SYSTEM & PANEL BOARDS. FOR PROTECTION OF THE ABOVE TO FEED THEIR CONTROL SYSTEMS AND SWITCH GEARS. |
| SPECIFICATION |
INPUT : HIGH VOLTAGE & HIGHER CURRENT OF POWER SYSTEMS
OUTPUT : PT - 110 V OR AS PER REQUIREMENTS.
COOLING: AN / ANON
CONSTRUCTION : OIL IMMERSED / RESIN CAST / OPEN TYPE.
|
| BENIFITS |
DESIGN AS PER REQUIREMENTS. CONFIRMING TO STANDARDS, INDOOR / OUTDOOR DESIGN, HIGHER PRECISION LEVEL. |
|
 
|
| A.C HIGH VOLTAGE TEST SET |
| ITEM |
A.C HIGH VOLTAGE TEST SETS (LOW POWER) UP TO 100 KV |
| APPLICATION |
TESTING OF COILS, CABLES, TRANSFORMERS ETC. |
| SPECIFICATION |
INPUT : 230 / 440 V, 1 PH 50HZ 5% +/-
OUTPUT : UP TO 100 KV
CURRENT SETTING: UP TO 500MA
AMBIENT TEMP : 50 DEGREES C
HUMIDITY : 100% MAXIMUM
ATMOSPHERE : DUSTY / HYGROSCOPIC
INSTALLATION : INDOOR PORTABLE
ALTITUDE : 1000M ABOVE M.S.L
TEMP. RISE : 55 DEGREES C
TEMP. LIMIT OF
INSULATION : 115 DEGREES C
DUTY : ½ HOUR ON / ½ HOUR OFF
OVERLOAD : 10%
METHOD OF
COLLING : ONAN
PRIMARY CURRENT
OVERLOAD LIMIT : 2.5 TIMES FULL LOAD
OPERATION : MANUAL / MOTORIZED (OPTIONAL)
CURRENT RELATION : OPTIONAL
|
| BENIFITS |
SINGLE TWO PART CONSTRUCTION, MEMORY SET UP FOR O/P VOLTAGE, OVERLOAD / TRIPPING CURRENT SETTING, BROUGHT OUT H.T TERMINAL BUSHING, MULTIPLE OPERATOR SAFEGUARD, DIGITAL / ANALOGUE METERING (OPTIONAL), EFFECTIVE SURGE SUPPRESSOR, TIME SETTING ARRANGEMENT.
|
|

|
| D.C HIGH TENSION POWER SUPPLY |
| ITEM |
D.C HIGH TENSION POWER SUPPLY UP TO 100 KV, WITH CURRENT CAPACITIES UP TO 350mA. |
| APPLICATION |
TESTING OF INSULATION LEVEL & ISOLATION OF CONDUCTORS IN WINDINGS & CABLES ETC. |
| SPECIFICATION |
INPUT : 230 / 440 V, 1 PH 50HZ 5% +/-
OUTPUT : UP TO 100 KV D.C
CAPACITY : UP TO 350MA
AMBIENT TEMP : 50 DEGREES C
HUMIDITY : 100% MAXIMUM
ATMOSPHERE : DUSTY / HYGROSCOPIC
INSTALLATION : INDOOR PORTABLE
ALTITUDE : 1000MTR OVER MSL
TEMP. RISE : 55 DEGREES C
TEMP. LIMIT OF
INSULATION : 115 DEGREES C
DUTY : ½ HOUR ON / ½ HOUR OFF
OVERLOAD : 10%
METHOD OF
COLLING : ONAN / AN
PRIMARY OVER
CURRENT LIMIT : 2.5 TIMES OVERLOAD
OPERATION : MANUAL / AUTOMATIC
CURRENT SELECTION : OPTIONAL
|
| BENIFITS |
COMPACT DESIGN, DIRECT OUTPUT METERING, OVERLOAD / TRIPPING CURRENT PROTECTION AND SETTINGS, BROUGHT OUT H.T TERMINAL, MULTIPLE OPERATOR SAFEGUARDS, ALARM / INDICATION DIGITAL / ANALOGUE METERING (OPTIONAL), + VE / - VE EARTHING ARRANGEMENT.
|
|

|
| CURRENT INJECTION SET |
| ITEM |
CURRENT INJECTION SET |
| APPLICATION |
TEST IN OF RELAYS AND METER |
| SPECIFICATION |
INPUT : 230 / 440 V, 1 PH 50 MZ AC.
OUTPUT : 1.7 V.
CURRENT : 4000 AMPS.
COOLING : AIR NATURAL
OPERATION : MANUAL
INSTALLATION : INDOOR AS WELL AS OUTDOOR (PORTABLE)
ATMOSPHERE : DUSTY / HYGROSCOPE
TEMP. RISE : 115 C
|
| BENIFITS |
COMPACT DESIGN, LONG LIFE, TROUBLE FREE IF USED WITHIN ELECTRICAL, MECHANICAL AND ENVIRONMENTAL LIMITATIONS |
|

|
| OIL TEST SET |
| ITEM |
TRANSFORMER OIL TEST SETS 50, 60, 100 KV. |
| APPLICATION |
FOR TESTING THE DIELECTRIC STRENGTH OF TRANSFORMER INSULATION OIL. |
| SPECIFICATION |
INPUT : 230 V 1 PH 50 HZ A.C 5% +/-
OUTPUT : 0 - 50 / 60/100 KV
CURRENT : 20MA SETTING
HUMIDITY : 100% MAXIMUM
ATMOSPHERE : DUSTY / HYGROSCOPIC
INSTALLATION : INDOOR / PORTABLE
ALTITUDE : 1000M ABOVE M.S.L
TEMP. RISE : 55 DEGREES C
DUTY : INTERMITTENT
OVERLOAD : 10%
METHOD OF
COOING : A.N
OPERATION : MANUAL / MOTORIZED
CONTROL : FAST ACTING SEMI CONDUCTOR CONTROL.
|
| BENIFITS |
COMPACT DESIGN, VISUAL ALARM TEST ASSESSMENT, BREAK DOWN VOLTAGE MEMORY SET UP, DIGITAL / ANALOGUE METERING (OPTIONAL), OPERATOR SAFEGUARD ARRANGEMENT. |
|

|
| METER TEST BENCH |
| ITEM |
METER TEST BENCH |
| APPLICATION |
TESTING AND CALIBRATION OF 3 PHASE 3 WIRE. ACTIVE & REACTIVE TYPE ENERGY METERS. |
| SPECIFICATION |
INPUT : 415 V, 3 PHASE, 50 HZ AC.
INPUT TOLERANCE : +/- 15%
OUTPUT : 0-63.5 X 3 / 240 X 3 V.
CAPACITY : 200 VA / PHASE
CURRENT : 0-1 / 2.5 / 5 / 10 / 25 / 50 / 100 A
CAPACITY : 200 VA / PHASE
PHASE SHIFT : 0-360 IN STEPS OF 30 DEGREE COARSE CONTROL 15 LAG - 15 LEAD STEP LESS FINE CONTROL.
INSTALLATION : INDOOR USE ONLY.
METHOD OF
COOLING : AIR NATURAL
OPERATION : MANUAL
AMBIENT TEMP. : 45 C.
|
|

|
| RELAY TEST SET |
| ITEM |
RELAY TEST SET TO TEST |
| APPLICATION |
TO TEST EQUIPMENT WORKING ON A.C. VOLTAGE OR CURRENT RELAYS, CURRENT TRANSFORMER. |
| SPECIFICATION |
INPUT : 230 V, 1 PHASE 50 HZ A.C.
OUTPUT 0/75/300 V.
CAPACITY : 100 VA, 100AMPS.
INSTALLATION : INDOOR ONLY
METHOD OF
COOLING : AIR NATURAL
PRIMARY CURRENT : UP TO 1000AMPS.
DUTY : CONTINUOUS
CURRENT RELATION : OPTIONAL
EFFICIENCY : MORE THAN 80%
TEMP. RISE : 115C
OVERLOAD : 10%
|
| BENIFITS |
SINGLE / TWO PART CONSTRUCTION CURRENT REGULATOR, RISK-FREE OPERATION, PROTECTION FOR TRANSFORMER AND METERS. DESIGNED AND DEVELOPED AS REQUIRED SPECIFICATIONS. |
|
| |
|